CO2 Solenoid Timing for a Split-Photoperiod (Siesta) Light Schedule

Keep your pressurized CO2 solenoid ON continuously if your midday siesta is 2 hours or shorter, and cycle it OFF during the siesta if the dark gap is 3 hours or longer—restarting CO2 1 to 1.5 hours before the afternoon light block begins. Turning CO2 off during a short 1–2 hour break starves plants when the second light block fires because dissolved CO2 takes 60–120 minutes to re-saturate to 25–30 ppm, whereas leaving CO2 injecting through a 3–5 hour dark period wastes gas and risks pushing dissolved CO2 past safe levels while photosynthesis is paused.


Siesta Length vs. Solenoid Strategy

The length of your dark midday gap—not your total daily light hours—determines whether you run one continuous CO2 block or two separate pulses. Use the decision matrix below to match your siesta duration to the correct timer or controller behavior.

Siesta (Dark Gap) Length Timer-Controlled Solenoid Action pH-Controller Solenoid Action Why This Works
1.0–2.0 hours (Short siesta) Leave CO2 ON continuously from 1–2 hr before Light Block 1 until 1 hr before Light Block 2 ends. Auto-regulates continuously Off-gassing over 1–2 hr is minor; cycling OFF creates a CO2 deficit when Light Block 2 starts.
2.5–3.5 hours (Medium siesta) Cycle OFF 30 min before Light Block 1 ends; cycle ON 1 hr before Light Block 2 starts. Auto-regulates continuously Prevents midday CO2 buildup while giving a full 60-minute ramp-up before afternoon PAR hits.
4.0–6.0 hours (Long siesta) Cycle OFF 45–60 min before Light Block 1 ends; cycle ON 1.5 hr before Light Block 2 starts. Auto-regulates continuously Saves 20–30% CO2 gas and prevents excess accumulation during long non-photosynthetic periods.
  • Lighting budget rule: Keep combined light blocks within 7–8 hours/day for medium-light planted tanks (30–50 PAR at the substrate) or 6–8 hours/day for high-light planted tanks (50–100+ PAR at the substrate, pressurized CO2 required). Splitting the photoperiod into two 3–4 hour blocks lets you view the tank morning and evening without exceeding your daily PAR budget.

Ready-to-Program Split-Photoperiod Schedules

Program your solenoid timer using fixed lead and lag offsets relative to each light block rather than matching light ON/OFF times. The three schedules below cover the most common 7-hour and 6-hour daily light budgets.

Schedule A: 2-Hour Siesta (Continuous CO2, 7 Hours Total Light)

Best for tanks where lights run 3.5 hours in the morning and 3.5 hours in the afternoon with a brief midday break.

Time of Day Event Equipment State Duration / Offset
7:00 AM CO2 Solenoid ON Lights OFF, CO2 ON 1.5 hr before Light Block 1
8:30 AM Light Block 1 ON Lights ON, CO2 ON 3.5 hr light block
12:00 PM Light Block 1 OFF (Siesta Starts) Lights OFF, CO2 stays ON 2.0 hr dark gap
2:00 PM Light Block 2 ON Lights ON, CO2 ON 3.5 hr light block
4:30 PM CO2 Solenoid OFF Lights ON, CO2 OFF 1.0 hr before Light Block 2 ends
5:30 PM Light Block 2 OFF Lights OFF, CO2 OFF End of photoperiod
  • Total CO2 runtime: 9.5 hours/day
  • Total light runtime: 7.0 hours/day

Schedule B: 4-Hour Siesta (Dual-Pulse CO2, 7 Hours Total Light)

Best for morning-and-evening viewing (for example, before work and after work) with a 4-hour midday dark period.

Time of Day Event Equipment State Duration / Offset
6:00 AM CO2 Pulse 1 ON Lights OFF, CO2 ON 1.5 hr before Light Block 1
7:30 AM Light Block 1 ON Lights ON, CO2 ON 3.5 hr light block
10:15 AM CO2 Pulse 1 OFF Lights ON, CO2 OFF 45 min before Light Block 1 ends
11:00 AM Light Block 1 OFF (Siesta Starts) Lights OFF, CO2 OFF 4.0 hr dark gap
1:30 PM CO2 Pulse 2 ON Lights OFF, CO2 ON 1.5 hr before Light Block 2
3:00 PM Light Block 2 ON Lights ON, CO2 ON 3.5 hr light block
5:30 PM CO2 Pulse 2 OFF Lights ON, CO2 OFF 1.0 hr before Light Block 2 ends
6:30 PM Light Block 2 OFF Lights OFF, CO2 OFF End of photoperiod
  • Total CO2 runtime: 8.25 hours/day (4.25 hr Pulse 1 + 4.0 hr Pulse 2)
  • Total light runtime: 7.0 hours/day

Schedule C: 5-Hour Siesta (High-PAR Dual-Pulse CO2, 6 Hours Total Light)

Best for high-light 50–100+ PAR setups running two 3-hour blocks separated by a long 5-hour midday gap.

Time of Day Event Equipment State Duration / Offset
6:30 AM CO2 Pulse 1 ON Lights OFF, CO2 ON 1.5 hr before Light Block 1
8:00 AM Light Block 1 ON Lights ON, CO2 ON 3.0 hr light block
10:15 AM CO2 Pulse 1 OFF Lights ON, CO2 OFF 45 min before Light Block 1 ends
11:00 AM Light Block 1 OFF (Siesta Starts) Lights OFF, CO2 OFF 5.0 hr dark gap
2:30 PM CO2 Pulse 2 ON Lights OFF, CO2 ON 1.5 hr before Light Block 2
4:00 PM Light Block 2 ON Lights ON, CO2 ON 3.0 hr light block
6:00 PM CO2 Pulse 2 OFF Lights ON, CO2 OFF 1.0 hr before Light Block 2 ends
7:00 PM Light Block 2 OFF Lights OFF, CO2 OFF End of photoperiod
  • Total CO2 runtime: 7.75 hours/day (3.75 hr Pulse 1 + 4.0 hr Pulse 2)
  • Total light runtime: 6.0 hours/day

Why Pre-Charge and Early-Shutoff Offsets Work

Dissolved CO2 lags behind solenoid switching by 60 to 120 minutes because gas transfer and drop-checker diffusion are gradual, not instant. Understanding how tank volume, filter turnover, and depth affect that curve keeps both light blocks in the 25–30 ppm sweet spot.

Starting Injection Rates (BPS) by Tank Size

Calibrate your needle valve to a 4 dKH drop checker showing lime green (~25–30 ppm) before fine-tuning your siesta timer offsets. Use these starting bubble-per-second (BPS) ranges:

  • 10 gal (38 L): 0.5–1 BPS
  • 20 gal (76 L) — 20H or 20L: 1–1.5 BPS
  • 40B (151 L): 2–3 BPS
  • 75 gal (284 L): 3–5 BPS

How Tank Depth and Filter Turnover Shift Your Timing

  • Filter turnover (6–10×/hr empty-box GPH): High-tech CO2 planted tanks require 6–10×/hr rated filter turnover to sweep microbubbles across plant leaves. Tanks near 10×/hr with brisk surface ripple off-gas CO2 faster during a 4-hour siesta, so Pulse 2 needs the full 1.5-hour pre-charge (or 2 hours in heavily agitated open-top tanks). Tanks closer to 6×/hr with gentle surface movement retain more residual CO2 across a 3–4 hour siesta, so a 1-hour Pulse 2 pre-charge is often sufficient.
  • Shallow vs. deep tanks: Shallow tanks ≤12 in (30 cm) tall—such as a 10G (20 × 10 × 12 in / 51 × 25 × 30 cm), 20L (30 × 12 × 12 in / 76 × 30 × 30 cm), or 33L (48 × 13 × 12 in / 122 × 33 × 30 cm)—have a high surface-area-to-volume ratio and off-gas CO2 faster during a siesta than deep tanks 21–24+ in (53–61+ cm) tall—such as a 55G (48 × 13 × 21 in / 122 × 33 × 53 cm), 75G (48 × 18 × 21 in / 122 × 46 × 53 cm), or 90G (48 × 18 × 24 in / 122 × 46 × 61 cm). Conversely, deep tanks take longer to circulate freshly injected CO2 down to the substrate, which is why deep tanks benefit from the full 1.5–2 hour Pulse 1 and Pulse 2 lead times.
  • Why turn CO2 OFF 30–45 minutes before Block 1 ends (instead of 60 minutes)? Unlike the end of the day—when the tank enters an 8–12 hour overnight dark period—Block 1 is followed by a shorter siesta. Turning CO2 off 30–45 minutes before Block 1 ends uses up excess dissolved gas before darkness while leaving a small residual base so Pulse 2 recovers faster.

Step-by-Step Calibration for a Dual-Pulse Schedule

Always tune your needle valve BPS first, then verify both light blocks at two separate drop-checker checkpoints. Remember that a 4 dKH drop checker lags actual water-column CO2 by 1 to 2 hours, so never adjust your needle valve based on a reading taken 15 minutes after a timer change.

  1. Lock your light schedule first. Set your digital light timer to two equal blocks (for example, 3.5 hr + 3.5 hr or 3 hr + 3 hr) and record your exact siesta duration.
  2. Program your solenoid timer offsets. Apply Schedule A (continuous) for a 1–2 hour siesta, or Schedule B/C (dual-pulse) for a 3–6 hour siesta. Verify that your digital outlet timer or smart plug supports at least two independent ON/OFF programs per day.
  3. Set starting BPS and wait 48 hours. Dial in the starting BPS for your tank volume, ensure an inline check valve is installed between the bubble counter and diffuser/reactor, and let the schedule run for two full days.
  4. Read Checkpoint 1 (30 minutes into Light Block 1). Because the 4 dKH drop checker lags 1–2 hours, reading it 30 minutes after Light Block 1 turns on reflects the CO2 concentration built up right as the morning lights fired.
    • Blue or dark green: Increase Pulse 1 lead time by 30 minutes (up to 2 hours) or increase BPS by 10–15%.
    • Lime green (~25–30 ppm): Morning ramp-up is dialed in.
    • Bright yellow: Shorten Pulse 1 lead time to 1 hour or reduce BPS by 10–15%.
  5. Read Checkpoint 2 (30 minutes into Light Block 2). This reading reflects the CO2 level at the exact moment the afternoon lights turned on.
    • Blue or dark green while Checkpoint 1 was lime green: Your BPS is fine, but Pulse 2 needs more pre-charge time. Move Pulse 2 ON 30 minutes earlier (for example, from 1.0 hr to 1.5 hr before Light Block 2), or shorten the early shutoff before Block 1 ends from 45 min to 30 min.
    • Bright yellow while Checkpoint 1 was lime green: Residual CO2 did not off-gas enough during the siesta. Move Pulse 1 OFF 15–30 minutes earlier, or shorten Pulse 2's pre-charge from 1.5 hr to 1.0 hr.
    • Lime green (~25–30 ppm): Both blocks are synchronized.

Five Common Split-Photoperiod Solenoid Pitfalls

Most algae blooms and livestock stress on split-photoperiod tanks trace back to treating the second light block like a minor top-off rather than a second dawn.

  • Pitfall 1: Restarting CO2 only 15–30 minutes before Light Block 2. After a 3–5 hour siesta, dissolved CO2 has off-gassed substantially. Firing 50–100+ PAR lights while CO2 is still climbing from 10 ppm toward 25–30 ppm creates carbon starvation, triggering black beard algae (BBA) and staghorn algae. Fix: Always give Pulse 2 a full 1–1.5 hour pre-charge.
  • Pitfall 2: Leaving CO2 ON through a 4–6 hour siesta without a pH controller. With lights off and photosynthesis paused, continuous injection accumulates dissolved CO2 above 35–40+ ppm, especially in tanks with tight lids or gentle surface flow. Fix: Cycle the solenoid OFF during any siesta of 3 hours or longer, or use a calibrated pH controller.
  • Pitfall 3: Chasing a lagging 4 dKH drop checker mid-siesta. Adjusting the needle valve because the drop checker looks blue or yellow right after a light transition leads to over-correcting. Fix: Only evaluate changes at Checkpoint 1 and Checkpoint 2 after at least one full cycle.
  • Pitfall 4: Bright ambient window light hitting the tank during the siesta. Direct sunlight during the midday "dark" period keeps plants photosynthesizing at low light while CO2 is off, turning the siesta into an extended low-light photoperiod with depleted carbon. Fix: Block direct sunlight with blinds or a tank background during the siesta, or switch to a single uninterrupted photoperiod.
  • Pitfall 5: Skipping a check valve on a dual-pulse system. Dual-pulse schedules double the daily ON/OFF cycles of the solenoid (two depressurizations per day instead of one). Each time the solenoid closes, cooling gas inside the tubing creates slight negative pressure that draws tank water backward toward the regulator. Fix: Install a dedicated CO2-rated check valve close to the tank rim and inspect it whenever you refill the cylinder.

When a Single Uninterrupted Photoperiod Is Better

Skip the split photoperiod if your viewing hours already overlap with a single 6–8 hour window. A split photoperiod does not increase plant growth rate compared to a single uninterrupted block of equal total PAR; its primary advantage is aligning lighting with morning and evening viewing hours. If you are home during a continuous 6–8 hour block—or if managing two daily CO2 ramp-ups causes persistent BBA from fluctuating ppm—switch to one continuous 6–8 hour light block with the solenoid ON 1–2 hours before lights on and OFF 1 hour before lights off.