Overflow Combs, Weir Screens, and Integrated Intake Slots

An overflow comb or integrated intake slot should pass your tank's full filter turnover (3–10×/hr depending on livestock) at a water rise of 1/4 to 3/8 in (6–10 mm) above the slot base while blocking livestock and floating debris. For standard slotted combs with 50% open area, size for 40–65 GPH per linear inch (60–100 L/hr per cm) of total comb width—or 100–150 GPH per linear inch (150–225 L/hr per cm) for a flat, toothless weir—and add a 400–600 micron (0.016–0.024 in / 0.4–0.6 mm) mesh screen or 30–40 PPI foam baffle whenever keeping shrimp or fry.


How Overflow Combs, Weir Screens, and Intake Slots Control Flow

Overflow hardware sets both the display tank's surface water height and the maximum safe flow rate your return pump can deliver without flooding the rim or starving the pump chamber.

Three distinct intake styles appear in freshwater all-in-one (AIO) partitions and internal/external overflow boxes:

  • Toothed Overflow Combs: Vertical slots cut into the top edge of an acrylic wall or removable weir plate. Teeth block floating leaves and fish while skimming the top 1/8–1/4 in (3–6 mm) surface film.
  • Weir Screens and Flat Weirs: A smooth, toothless horizontal spill edge paired with a removable mesh screen or slotted guard. Removing the teeth roughly doubles flow capacity per inch and eliminates trickle noise, though fine mesh clogs faster in planted tanks.
  • Integrated Mid-Water and Bottom Intake Slots: Secondary grates cut 4–14 in (10–36 cm) below the waterline in AIO rear walls. They pull suspended waste from lower water columns and keep the pump fed if evaporation drops the display below the top comb, but they reduce surface-skimming pull unless partially baffled.

Core Sizing Formulas

Use these plain-text calculations to verify any existing comb or size a custom partition:

  • Target Flow (GPH) = Tank Volume (gal) × Turnover Rate (3–10×/hr)
  • Comb Open Ratio = Slot Width (in) ÷ (Slot Width (in) + Tooth Width (in))
  • Effective Open Width (in) = Total Comb Length (in) × Comb Open Ratio
  • Safe Slotted Comb Length (in) = Target Flow (GPH) ÷ 50 (assumes 50% open area and a 25% safety margin for biofilm buildup)
  • Safe Flat Weir Length (in) = Target Flow (GPH) ÷ 120 (for toothless edges with wide-aperture guards)

Sizing Combs and Weirs by Tank Size and Livestock Turnover

Match your linear comb length to the tank's realistic GPH turnover rather than tank width alone, because high-flow goldfish and cichlid setups need twice the weir length of planted or nano tanks.

Tank Size (Nominal) Dimensions (L × W × H) Typical Ecosystem & Turnover Target Flow Range Min. Slotted Comb Length (50% Open) Min. Flat Weir Length
5–5.5 gal (19–21 L) 16 × 8 × 10 in (41 × 20 × 25 cm) Betta or shrimp (3–4×/hr) 15–22 GPH (57–83 L/hr) 2–3 in (5–8 cm) 1.5 in (4 cm)
10 gal (38 L) 20 × 10 × 12 in (51 × 25 × 30 cm) Betta, shrimp, or nano (3–4×/hr) 30–40 GPH (114–151 L/hr) 3–4 in (8–10 cm) 2 in (5 cm)
20L (76 L) 30 × 12 × 12 in (76 × 30 × 30 cm) Community/low-tech planted (4–6×/hr) 80–120 GPH (303–454 L/hr) 4–5 in (10–13 cm) 2–3 in (5–8 cm)
29 gal (110 L) 30 × 12 × 18 in (76 × 30 × 46 cm) Fancy goldfish or planted (6–8×/hr) 175–230 GPH (662–871 L/hr) 5–6 in (13–15 cm) 3 in (8 cm)
40B (151 L) 36 × 18 × 16 in (91 × 46 × 41 cm) Shrimp/planted (4–6×/hr) or cichlids (8–10×/hr) 160–400 GPH (606–1,514 L/hr) 6–8 in (15–20 cm) 3.5–4 in (9–10 cm)
55 gal (208 L) 48 × 13 × 21 in (122 × 33 × 53 cm) High-tech CO2 planted or cichlids (6–10×/hr) 330–550 GPH (1,249–2,082 L/hr) 8–11 in (20–28 cm) 4.5–5 in (11–13 cm)
75 gal (284 L) 48 × 18 × 21 in (122 × 46 × 53 cm) Single-tail goldfish or cichlids (8–10×/hr) 600–750 GPH (2,271–2,839 L/hr) 12–15 in (30–38 cm) 6–7 in (15–18 cm)
125 gal (473 L) 72 × 18 × 22 in (183 × 46 × 56 cm) Goldfish or African cichlids (8–10×/hr) 1,000–1,250 GPH (3,785–4,732 L/hr) 20–25 in (51–64 cm) 9–11 in (23–28 cm)

Head Height and Rim Clearance

Water must rise slightly above the bottom of the comb slots to push through them. Keep normal operating head height between 1/4 and 3/8 in (6–10 mm):

  • Under 1/8 in (3 mm) head height: The comb is oversized for the pump or the pump is turned too low. Surface film skims slowly, and slight evaporation breaks the siphon/flow over the weir.
  • Over 5/8 in (16 mm) head height: The comb is undersized or partially clogged. The slots submerge completely, stopping surface-film removal and eating into the 1/2–3/4 in (13–19 mm) freeboard on rimless tanks.

Slot Width, Weir Screen Mesh, and Livestock Safety

Choose slot spacing and screen mesh based on the smallest animal in the tank, then add linear weir length to keep intake velocity low enough that weak swimmers are not pinned against the grate.

Livestock Profile (Realistic Tank Bounds) Recommended Comb Slot Width Secondary Screen / Guard Key Intake Hazard to Prevent
Ornamental Shrimp (5–40B / 19–151 L) 1/16–1/8 in (1.6–3.2 mm) 400–600 micron (0.016–0.024 in / 0.4–0.6 mm) stainless mesh or 30–40 PPI foam block behind comb Shrimplets (1/16–1/8 in / 1.5–3 mm) slip through bare 1/8 in (3.2 mm) slots into filter chambers
Long-Finned Betta (5–20L / 19–76 L) 1/8 in (3.2 mm) 20–30 PPI coarse sponge behind comb; oversize comb length by 50% High suction velocity through narrow slots pulls and tears flowing fins
Nano & Community Fish (10–55G / 38–208 L) 1/8 in (3.2 mm) Optional 1/8 in (3.2 mm) plastic mesh guard over toothless weirs Slender rasboras, tetras, or kuhli loaches squeezing through 3/16–1/4 in (4.8–6.4 mm) slots
High-Tech Planted (20L–90G / 76–341 L) 3/16 in (4.8 mm) Removable 1/4 in (6.4 mm) wide-mesh screen + floating plant corral Stem trimmings and duckweed damming 1/8 in (3.2 mm) teeth within hours of pruning
Fancy Goldfish (29–75G / 110–284 L) & Single-Tail / Cichlids (40B–125G / 151–473 L) 3/16–1/4 in (4.8–6.4 mm) 1/4–3/8 in (6.4–9.5 mm) rigid plastic grid (egg-crate or needlepoint canvas) Large waste, uprooted plants, and 8–10×/hr flow backing up narrow slots

Avoiding Fin-Pinning Velocity

Suction speed at the intake depends on open area, not pump GPH alone. Doubling a comb's length—for example, from 3 in (7.6 cm) to 6 in (15.2 cm) on a 10 gal (38 L) betta tank running 35 GPH (132 L/hr)—cuts water velocity through each slot in half while maintaining the exact same filter turnover.


Balancing Top Overflow Combs with Lower Intake Slots

Integrated lower intake slots steal 40–70% of surface-skimming flow because water pressure is higher at depth; partially baffle them whenever oily surface film builds up.

Many AIO partitions place a second intake grate halfway down the back wall or 2 in (5 cm) above the substrate. Because water pressure increases with depth, the lower slot pulls far more water per square inch than the top overflow comb.

How to Tune Dual-Zone Intakes

  1. Test surface skimming first: Sprinkle a tiny pinch of crushed flake food or watch for surface biofilm under the lights. If floating particles circle the display without entering the top comb within 1–2 minutes, the lower slot is stealing too much flow.
  2. Partially restrict the lower grate: Slide a thin acrylic cover, silicone plug, or 20–30 PPI foam insert over 50–80% of the lower slot area. Do not seal it permanently with silicone if your return chamber holds less than 10% of total tank volume.
  3. Verify the 1/4 in (6 mm) safety bypass: Leaving a small 1/4–3/8 in (6–10 mm) gap at the lower slot keeps water moving into the rear chamber if floating plants temporarily mat across the top comb.
  4. Watch evaporation behavior: In any AIO or sump system, evaporation only drops the water level in the return pump chamber, never in the display tank—until the pump chamber runs dry or the top comb is starved.

Step-by-Step Maintenance and Clog Prevention

Clean overflow combs and weir screens weekly during water changes, and monitor the water-height differential between the display tank and the first filter chamber.

  1. Brush the teeth vertically: Use a stiff bottle brush or dedicated toothbrush with downward strokes while siphoning water out, so loosened biofilm goes into the bucket rather than back into the display.
  2. Swap and rinse fine weir screens: If using 400–600 micron (0.4–0.6 mm) shrimp mesh or 30–40 PPI foam behind the comb, keep a spare clean screen ready. Swap it in, then rinse the fouled screen in old tank water.
  3. Corral floating plants: Keep duckweed, frogbit, or salvinia at least 2–3 in (5–8 cm) away from the overflow comb using a floating airline tubing ring anchored with a suction cup.
  4. Quiet trickle noise: If water drops more than 1.5 in (3.8 cm) over the comb into the first chamber and sounds like a faucet, raise the water level in the rear/sump chamber by adding a 1/2–1 in (1.3–2.5 cm) taller baffle strip or placing a strip of 20 PPI coarse foam diagonally against the wet side of the weir to break the fall.

Common Intake Pitfalls and Quick Fixes

Most overflow failures come from undersized slot area, unguarded fine mesh, or placing tall plants directly against the weir.

  • Display water slowly creeping toward the rim: Biofilm, snail shells, or plant leaves are blocking 30%+ of the comb slots. Brush the comb immediately and check if the return pump chamber simultaneously dropped 1/2–1 in (1.3–2.5 cm).
  • Shrimp or nano fish turning up in the back chamber: Bare 1/8 in (3.2 mm) comb slots or a gap between a removable comb and the tank trim let livestock slip through. Back the comb with 400–600 micron (0.4–0.6 mm) mesh or wedge a 30–40 PPI foam strip flush against the inside of the slots, leaving zero gap at the top edge.
  • Persistent oily surface film despite 6×/hr flow: Lower intake slots are bypassing the top weir, or the comb slots are completely submerged because the display water level is too high. Baffle 75% of the lower slots and lower the rear-chamber water level slightly until water actively cascades 1/4–1/2 in (6–13 mm) over the top weir edge.
  • Return pump sucking air bubbles every few hours: Fine weir mesh (<400 micron) or 40 PPI foam behind the comb is clogging faster than your top-off schedule, starving the rear chamber while raising the display level. Switch to a larger 3/16 in (4.8 mm) comb or 20–30 PPI foam block with a 1/2 in (13 mm) lower-than-rim emergency bypass gap over the top of the partition.