Clean a bare-bottom fry or breeding tank by siphoning uneaten food and waste daily with 3/16 in (5 mm) airline tubing or 3/8 in (10 mm) vinyl hose into a white 5 gal (18.9 L) inspection bucket, replacing 10%–25% of the water daily (or 30%–50% every 2–3 days once fry are free-swimming and eating solid foods), wiping biofilm off the bare glass once a week, and refilling with dechlorinated water matched within ±1–2°F (±0.5–1°C).

Cleaning Schedule by Tank Size and Fry Stage

Small, frequent water changes keep ammonia and nitrite at 0 ppm and prevent bacterial biofilm from fouling newly hatched fry without creating strong currents or large swings in temperature, pH, dGH, or dKH.

Fry Stage Typical Tank Size (L × W × H) Siphon Tubing ID Water Change Volume & Frequency Glass Wipe & Sponge Rinse
Eggs & wrigglers 5G (16 × 8 × 10 in / 41 × 20 × 25 cm) to 10G (20 × 10 × 12 in / 51 × 25 × 30 cm) 3/16 in (5 mm) airline tubing or 1/4 in (6 mm) hose 10%–15% daily (spot-siphon fungus/detritus only) Skip glass wipes until free-swimming; no sponge rinse
Newly hatched free-swimming fry (Weeks 1–3) 10G (20 × 10 × 12 in) to 20L (30 × 12 × 12 in / 76 × 30 × 30 cm) 3/16 in (5 mm) airline tubing, or 1/4 in (6 mm) with mesh guard 15%–25% daily after last feeding Wipe bottom and walls gently once weekly; squeeze sponge every 2 weeks
Active juvenile grow-out (Weeks 4–8) 20H (24 × 12 × 16 in), 29G (30 × 12 × 18 in), or 40B (36 × 18 × 16 in) 3/8 in (10 mm) vinyl hose with finger-pinch or inline valve 25%–40% every 2 days Wipe all glass panels weekly; squeeze sponge every 1–2 weeks
Heavy-bioload grow-out (e.g., fancy goldfish or African cichlids) 40B (36 × 18 × 16 in) to 75G (48 × 18 × 21 in) 1/2 in (13 mm) vinyl hose with mesh screen 40%–50% every 2–3 days Wipe glass weekly; rinse sponge filters weekly in drained tank water

Fry-Safe Cleaning Equipment Setup

Use narrow-bore tubing, a high-contrast inspection bucket, and non-abrasive glass tools so every stray fry is visible and easy to return to the tank.

  • Precision siphon wand: Attach 4–6 ft (1.2–1.8 m) of 3/16 in (5 mm) flexible airline tubing to a rigid 3/16 in (5 mm) acrylic tube or zip-tie the flexible tip to a clean plastic chopstick. The rigid handle lets you steer the intake around fry without putting your hands in the tank.
  • Mesh-guarded grow-out siphon: For 3/8 in (10 mm) or 1/2 in (13 mm) vinyl hoses, stretch a piece of fine nylon mesh or a coarse pre-filter sponge sleeve over the intake end and secure it with a rubber band.
  • White 5 gal (18.9 L) inspection bucket: Always siphon into a clean white bucket dedicated solely to aquarium use. A full 5 gal (18.9 L) bucket of freshwater weighs roughly 41.7 lbs (18.9 kg) (8.34 lbs/gal or 1 kg/L), so fill it only halfway (2.5 gal / 9.5 L, about 20.9 lbs / 9.5 kg) if carrying it across a room.
  • Small-batch tools: Keep a 1–2 oz (30–60 mL) turkey baster or wide-bore pipette for spot-cleaning dead eggs and a smooth plastic spoon or specimen cup for transferring accidentally siphoned fry (dry nets crush tiny fins and gills).
  • Glass-wiping pad and flashlight: Use a plain, detergent-free polyester aquarium sponge pad or a clean microfiber cloth for wiping biofilm, plus a small LED flashlight to scan the drain bucket before discarding water.

Step-by-Step Bare-Bottom Cleaning Routine

Follow the same sequence every session—inspect, spot-siphon, wipe glass, siphon suspended film, rinse filter media, and slow-refill—so waste leaves the tank cleanly while beneficial bacteria and fry stay undisturbed.

  1. Power down heaters if water will drop near them: If your water change will expose any part of a submersible heater, unplug it 10 minutes before draining. Keep air-driven sponge filters running during light spot-siphoning, or shut off hang-on-back filters so food particles settle in the corners.
  2. Spot-siphon bottom waste into a white bucket: Start the siphon and hold the 3/16 in (5 mm) tip 0.25–0.5 in (6–13 mm) above the glass floor, sweeping slowly along the silicone seams and under sponge filter bases where uneaten Artemia nauplii, microworms, and powdered fry food collect.
  3. Wipe the bare glass walls and floor: Once a week, gently wipe the inside walls and bare bottom with a clean aquarium sponge pad before finishing the siphon. Heavy protein feedings create a slick, clear-to-cloudy bacterial biofilm on bare glass that traps waste and consumes oxygen if left untouched.
  4. Make a final siphon pass: After wiping the glass, wait 2–3 minutes for dislodged film to settle to the floor, then siphon it out until you reach your target water-change volume.
  5. Inspect the drain bucket with a flashlight: Shine a flashlight diagonally into the white bucket and wait 30 seconds for movement. Scoop out any siphoned fry with a plastic spoon or wide pipette and return them gently to the tank.
  6. Squeeze sponge filters in the drained water: Every 1–2 weeks (or whenever bubble output slows), lift one sponge filter at a time into the bucket of removed tank water and squeeze it 3–5 times until the thickest brown mulm clears. Never rinse sponge media under chlorinated tap water.
  7. Refill slowly with matched, conditioned water: Treat replacement water with a freshwater water conditioner before it enters the tank, and match temperature within ±1–2°F (±0.5–1°C) as well as dGH and dKH. Pour over a clean saucer, your hand, or a floating piece of clean filter foam, or drip-siphon back in from a raised bucket through 3/16 in (5 mm) airline tubing so fry are not tumbled.

Adjusting Cleaning by Breeding Setup and Hardware

Match your siphon flow, filtration turnover, and heater placement to the species and tank footprint so cleaning never stresses sensitive fry or disrupts thermal stability.

  • Bettas and ornamental shrimp (5G–20L for bettas; 5G–40B for shrimp): Keep empty-box filter turnover gentle at 3–4×/hr using air-driven sponge filters or intake-sponged, baffled filters. For newborn shrimplets and newly free-swimming betta fry, stick strictly to 3/16 in (5 mm) airline siphoning and limit single water changes to 10%–20% with matched dGH/dKH to avoid osmotic shock or molting failures. Never use copper-based products or algaecides in shrimp or fry tanks.
  • Egg-scatterers and bottom spawners (10G–29G): Corydoras, danios, and tetras lay eggs or rest wrigglers directly on bare glass. During the first 48–72 hours after hatching, only spot-clean unfertilized, fuzzing eggs with a pipette or 3/16 in (5 mm) tube; hold off on wiping the bottom glass until fry are swimming off the floor.
  • Large grow-out tanks (40B and larger; goldfish or African cichlids): Once fry grow past 0.75–1 in (19–25 mm) in 40B (36 × 18 × 16 in) to 75G (48 × 18 × 21 in) grow-outs—scaling up to 8–10×/hr empty-box filtration for heavy-bioload goldfish or African cichlids—use a 3/8 in (10 mm) or 1/2 in (13 mm) mesh-screened hose to clear waste faster.
  • Heating stability in bare-bottom tanks: Because bare glass lacks substrate thermal mass, water temperature swings faster during drains and refills. Standard heating baselines apply: 3–5 W/gal (0.8–1.3 W/L) for a 10°F (5.6°C) room-to-tank temperature difference (ΔT), or 5–7 W/gal (1.3–1.8 W/L) with a tight-fitting lid at ΔT ≈ 15–20°F (8.3–11.1°C). Tanks ≥40B or facing ΔT ≥ 20°F (11.1°C) should run dual heaters sized at 50%–60% of total wattage each on an external temperature controller, mounted low and angled near sponge-filter bubbles so they stay submerged during 25%–40% water changes.
  • Lighting for cleaning visibility: Bare-bottom breeding tanks only need low ambient or viewing light (15–30 PAR at the floor for 6–8 hr/day if Java moss or floating plants are present). Brighter light accelerates green algae and biofilm on bare glass without benefiting fry.

Common Pitfalls and How to Prevent Them

Avoiding five recurring mistakes prevents almost all cleaning-related fry losses in bare-bottom setups.

  • Using a standard gravel vacuum tube: Wide 1.5–2 in (38–51 mm) rigid gravel vacs generate too much suction for fry under 0.5 in (13 mm) and pin them against the intake. Keep wide tubes strictly for adult tanks and use 3/16 in (5 mm) airline tubing or a mesh-screened 3/8 in (10 mm) hose instead.
  • Skipping glass wipes because the water looks clear: Clear water can still hide a thick bacterial slime layer on the bare floor and walls where fry rest overnight. Wipe all four walls and the bottom weekly once fry are free-swimming.
  • Pouring cold or unconditioned tap water directly in: Even a 4–5°F (2.2–2.8°C) drop or trace chloramines can shock tiny fry and wipe out a spawn. Always verify replacement water temperature with a digital probe or thermometer and add water conditioner before refilling.
  • Rinsing every sponge filter at once: Cleaning all biological media on the same day—or squeezing sponges in tap water—can trigger an ammonia spike right after a heavy feeding. Alternate sponge filters on multi-sponge tanks and always rinse in removed tank water.