Aquarium Water Testing Units and Conversions
In freshwater aquariums, 1 ppm equals 1 mg/L, 1 dGH or 1 dKH equals 17.85 ppm (17.9 ppm rounded) as CaCO3, 1 meq/L equals 2.8 dKH (50 ppm CaCO3), and 1 mS/cm equals 1,000 µS/cm (roughly 500–700 ppm TDS depending on the meter's conversion factor). Use the formulas and lookup tables below to translate between US hobbyist test kits, digital meters, municipal water reports, and international care guides.
Master Water Testing Conversion Table
Most freshwater water-quality confusion comes from comparing kits or reports that measure the same ion on different scales.
| Parameter | Primary Unit | Equivalent Unit | Exact Conversion Formula | Quick Mental Rule |
|---|---|---|---|---|
| Dissolved Solids / Ions | ppm |
mg/L |
1 ppm = 1 mg/L |
Identical in freshwater |
| General Hardness | dGH |
ppm (CaCO3) |
ppm = dGH × 17.85 |
Multiply dGH by 18 |
| Carbonate Hardness | dKH |
ppm (CaCO3) |
ppm = dKH × 17.85 |
Multiply dKH by 18 |
| Alkalinity | meq/L |
dKH |
dKH = meq/L × 2.804 |
Multiply meq/L by 2.8 |
| Alkalinity | meq/L |
ppm (CaCO3) |
ppm = meq/L × 50.04 |
Multiply meq/L by 50 |
| Conductivity | mS/cm |
µS/cm |
µS/cm = mS/cm × 1,000 |
Move decimal 3 places right |
TDS (0.5 NaCl scale) |
ppm |
µS/cm |
ppm = µS/cm × 0.50 |
Divide µS/cm by 2 |
TDS (0.7 442 scale) |
ppm |
µS/cm |
ppm = µS/cm × 0.70 |
Multiply µS/cm by 0.7 |
| Nitrate (Ion vs. Nitrogen) | NO3- (ppm) |
NO3-N (ppm) |
NO3- = NO3-N × 4.427 |
Multiply NO3-N by 4.4 |
| Nitrite (Ion vs. Nitrogen) | NO2- (ppm) |
NO2-N (ppm) |
NO2- = NO2-N × 3.285 |
Multiply NO2-N by 3.3 |
| Ammonia (Ion vs. Nitrogen) | NH3 (ppm) |
NH3-N (ppm) |
NH3 = NH3-N × 1.216 |
Multiply NH3-N by 1.2 |
| Temperature | °F |
°C |
°C = (°F - 32) × 5 ÷ 9 |
Subtract 30, divide by 2 |
ppm vs. mg/L (and Nitrogen Ion vs. -N Scales)
In freshwater, 1 ppm (parts per million) and 1 mg/L (milligrams per liter) are interchangeable because 1 L of pure freshwater weighs 1 kg (1,000,000 mg). However, ammonia, nitrite, and nitrate tests can report either the total ion or only the nitrogen weight (-N), which changes the number by up to 4.43×.
- Nitrate (
NO3-vs.NO3-N): Municipal water reports and laboratory strips often report nitrate-nitrogen (NO3-N), while standard freshwater liquid reagent kits report total nitrate (NO3-).NO3- (ppm) = NO3-N (ppm) × 4.427NO3-N (ppm) = NO3- (ppm) × 0.226- Example: A city water report listing
10 ppm NO3-Nequals44.3 ppm NO3-on a standard hobbyist nitrate kit.
- Nitrite (
NO2-vs.NO2-N):NO2- (ppm) = NO2-N (ppm) × 3.285NO2-N (ppm) = NO2- (ppm) × 0.304
- Ammonia (
NH3/NH4+vs.NH3-N/ TAN): Standard liquid drop kits measure Total Ammonia Nitrogen (TAN), which combines toxic un-ionized ammonia (NH3) and much less toxic ammonium (NH4+).NH3 (ppm) = NH3-N (ppm) × 1.216NH4+ (ppm) = NH4-N (ppm) × 1.288NH3-N (ppm) = NH3 (ppm) × 0.822
- Why temperature and pH matter for ammonia: At
77°F (25°C)andpH 7.0, less than1%of TAN exists as toxicNH3. At82°F (27.8°C)andpH 8.0, roughly6%of the exact same TAN reading is toxicNH3.
Water Hardness: dGH, dKH, ppm (CaCO3), and meq/L
Multiply German degrees (dGH or dKH) by 17.85 to get ppm as CaCO3, and divide ppm by 17.85 (or multiply by 0.056) to convert back to degrees.
- General Hardness (
dGH): Measures dissolved calcium (Ca2+) and magnesium (Mg2+) ions.ppm (CaCO3) = dGH × 17.85dGH = ppm (CaCO3) ÷ 17.85
- Carbonate Hardness / Alkalinity (
dKH): Measures carbonate (CO3^2-) and bicarbonate (HCO3-) buffering capacity that resists pH swings.ppm (CaCO3) = dKH × 17.85dKH = ppm (CaCO3) ÷ 17.85meq/L = dKH ÷ 2.804(1 meq/L = 2.804 dKH = 50.04 ppm CaCO3)
- Regional hardness scales: Some municipal reports and imported test kits use Clark or French degrees instead of German degrees:
- Clark degrees (
°e):1 °e = 14.3 ppm CaCO3 = 0.80 dGH(dGH = °e × 0.80) - French degrees (
°f):1 °f = 10.0 ppm CaCO3 = 0.56 dGH(dGH = °f × 0.56)
- Clark degrees (
dGH or dKH |
ppm / mg/L (as CaCO3) |
meq/L (Alkalinity) |
Freshwater Water Profile |
|---|---|---|---|
1 |
17.9 |
0.36 |
Very soft (RO/DI remineralized start) |
2 |
35.7 |
0.71 |
Very soft (softwater dwarf shrimp) |
3 |
53.6 |
1.07 |
Soft |
4 |
71.4 |
1.43 |
Soft (ideal baseline for low-pH planted tanks) |
5 |
89.3 |
1.78 |
Soft to moderately soft |
6 |
107.1 |
2.14 |
Moderately soft (general community baseline) |
8 |
142.8 |
2.85 |
Moderately hard |
10 |
178.5 |
3.57 |
Hard |
12 |
214.2 |
4.28 |
Hard (livebearers, hardwater community) |
15 |
267.8 |
5.35 |
Very hard |
18 |
321.3 |
6.42 |
Very hard (rift-lake cichlid range) |
20 |
357.0 |
7.13 |
Extremely hard |
Titration Vial Volume Trick
Standard liquid GH and KH titration kits use a 5 mL water sample so that 1 drop = 1 dGH or 1 dKH. Adjusting the sample volume changes the resolution proportionally:
2.5 mLsample:1 drop = 2 dGH / dKH(saves reagent when testing very hard water above15 dGH/dKH).5 mLsample:1 drop = 1 dGH / dKH(standard resolution).10 mLsample:1 drop = 0.5 dGH / dKH(doubles precision for sensitive1–4 dGH/dKHsoftwater setups).
TDS (ppm) vs. Electrical Conductivity (µS/cm and mS/cm)
Digital TDS pens do not weigh dissolved solids; they measure electrical conductivity (EC in µS/cm or mS/cm) and multiply it by a preset conversion factor between 0.50 and 0.70. Because two meters can display different ppm numbers in the exact same water, conductivity (µS/cm) is the only universal cross-meter standard.
- Conductivity units:
1 mS/cm = 1,000 µS/cm(1 µS/cm = 0.001 mS/cm). - NaCl (
0.50) factor:TDS (ppm) = EC (µS/cm) × 0.50(standard on most budget aquarium TDS pens). - KCl (
0.55) factor:TDS (ppm) = EC (µS/cm) × 0.55. - 442 / Mixed Mineral (
0.70) factor:TDS (ppm) = EC (µS/cm) × 0.70(closer to natural freshwater mineral mixtures).
EC (µS/cm) |
EC (mS/cm) |
0.50 Scale (ppm) |
0.70 Scale (ppm) |
Typical Freshwater Context |
|---|---|---|---|---|
0–10 |
0.00–0.01 |
0–5 |
0–7 |
Pure RO/DI water |
100 |
0.10 |
50 |
70 |
Very softwater / remineralized shrimp water |
200 |
0.20 |
100 |
140 |
Softwater planted / South American biotope |
300 |
0.30 |
150 |
210 |
Moderate community water |
500 |
0.50 |
250 |
350 |
Moderately hard tap water |
800 |
0.80 |
400 |
560 |
Hard tap water |
1,000 |
1.00 |
500 |
700 |
Very hard / African cichlid buffer range |
Temperature Compensation (ATC) and the TDS vs. GH Trap
- Temperature shift: Water conductivity rises roughly
2%for every1.8°F(1°C) above77°F(25°C). Meters with Automatic Temperature Compensation (ATC) correct this automatically; non-ATC pens read artificially high in warm tropical tanks (78–82°F/25.6–27.8°C) and artificially low in coldwater tanks (65–68°F/18.3–20.0°C). - TDS is not GH: TDS counts every conductive ion—including sodium, chloride, potassium, nitrate, and bicarbonate—whereas
dGHonly measures calcium and magnesium. Water passed through a household ion-exchange softener reads0 dGHwhile keeping a high TDS because calcium and magnesium are swapped for sodium.
pH Scale and Temperature Conversions (°F to °C)
Every 1.0 unit on the pH scale represents a 10× change in hydrogen ion (H+) concentration, while water temperature converts linearly between Fahrenheit (°F) and Celsius (°C).
- pH logarithmic steps:
0.3pH change =2×change in acidity or alkalinity1.0pH change =10×change (e.g.,pH 6.0is10×more acidic thanpH 7.0)2.0pH change =100×change (pH 6.0is100×more acidic thanpH 8.0)
- Temperature formulas:
°C = (°F - 32) × 5 ÷ 9°F = (°C × 9 ÷ 5) + 32
Fahrenheit (°F) |
Celsius (°C) |
Common Freshwater Range |
|---|---|---|
65°F |
18.3°C |
Cool coldwater / temperate setups |
68°F |
20.0°C |
Standard coldwater baseline |
72°F |
22.2°C |
Subtropical / unheated indoor range |
75°F |
23.9°C |
Cool-end tropical community |
77°F |
25.0°C |
Standard lab & ATC meter calibration baseline |
78°F |
25.6°C |
Typical tropical community tank |
80°F |
26.7°C |
Warm tropical / betta baseline |
82°F |
27.8°C |
High-end tropical setups |
86°F |
30.0°C |
Warm-water specialty setups |
Diluting High-Range Water Samples
When a liquid reagent test hits the maximum color block on its chart (such as nitrate >80 ppm or >160 ppm), dilute the tank water sample with zero-mineral distilled or RO/DI water and multiply the test reading by the total dilution factor.
| Dilution Ratio | Tank Water (mL) |
Distilled / RO Water (mL) |
Multiply Result By | Example (5 mL Vial) |
|---|---|---|---|---|
1:1 (50%) |
2.5 mL |
2.5 mL |
2× |
Reading of 40 ppm = 80 ppm |
1:3 (25%) |
1.25 mL |
3.75 mL |
4× |
Reading of 40 ppm = 160 ppm |
1:4 (20%) |
1.0 mL |
4.0 mL |
5× |
Reading of 40 ppm = 200 ppm |
1:9 (10%) |
0.5 mL |
4.5 mL |
10× |
Reading of 20 ppm = 200 ppm |
- Use a syringe for small volumes: Measure
0.5 mLto2.5 mLwith a graduated oral syringe rather than eyeballing a test vial. - Never dilute pH tests: Distilled and RO/DI water have zero buffering (
0 dKH), so mixing them with tank water shifts the pH reading rather than scaling it. - Never dilute with tap water: Tap water contains its own hardness, nitrate, and chloramine/ammonia, which skews the multiplied result.
Common Water Testing Conversion Pitfalls
- Mixing up
NO3-andNO3-N: Reading a municipal water report of10 ppm NO3-Nas10 ppmon an aquarium scale underestimates actual nitrate by more than4×(44.3 ppm NO3-). - Comparing TDS readings across unknown meter scales: A reading of
200 ppmon a0.50NaCl pen equals400 µS/cm, which reads280 ppmon a0.70442 pen. Always recordµS/cmor note your meter's factor. - Treating
dGHanddKHas the same measurement: Total hardness (dGH) measures calcium and magnesium, while carbonate hardness (dKH) measures buffering capacity. A tank can have0 dKHand10 dGH, or12 dKHand0 dGH(common with softened water). - Reading the wrong part of the meniscus: In narrow
5 mLglass vials, fill until the bottom of the curved water surface (meniscus) sits squarely on the5 mLline at eye level. Reading the top edge leaves the vial slightly underfilled and inflates titration drop counts. - Applying
1 ppm = 1 mg/Lto solid weights without unit matching:1 ppmequals1 mgper1 L(1,000 mL), or3.785 mgper1 US gal(3.785 L). When calculating how much mineral salt raises10 gal(37.85 L) by10 ppm, multiply10 mg/L × 37.85 L = 378.5 mg(0.38 g).
Guides in this section
Related guides
- Reagent Shelf Life, Interference, and Repeat Verification
- Testing Ammonia in Freshwater Aquariums
- Testing Chlorine and Chloramine in Freshwater Tap and Batch Water
- Testing GH and KH by Drop Titration
- Digital pH, Conductivity, and TDS Meters for Freshwater Aquariums
- Freshwater Aquarium Test Strips, Liquid Kits, and Colorimeters